Page 1 of 8 By Jack Fegreus
published: Monday, May 05 2008
SANitize DAS to Enhance Virtual Infrastructure
With LeftHand Networks
Virtual Storage Appliance, branch offices and small business sites without a
SAN can leverage direct attached storage to create an iSCSI SAN and put VMs in
motion.
To derive maximal benefit from system virtualization,
storage virtualization is a necessary prerequisite. The mobility of a virtual
machine (VM) and its data plays an important role in daily operational tasks from
load balancing to system testing. That makes a SAN essential to leverage all
the advanced features of a VMware Virtual Infrastructure (VI) environment. The
issues of availability and mobility, however, really rise to the forefront in a
disaster recovery scenario:
While seldom an issue in datacenters, the ability to harness
the synergies of system and storage virtualization is often a major hurdle for
IT at smaller companies or remote branch locations. To remove that stumbling
block, LeftHand Networks has introduced their Virtual SAN Appliance (VSA) for
VMware ESX. In a few simple steps, a system administrator can employ two or
more VSAs, to create a fully redundant iSCSI SAN using previously isolated
direct attached storage on ESX servers.
LeftHand Networks’ Virtual SAN Appliance (VSA) opens the
door for SMB and remote office sites to create and manage a secure,
cost-effective, and fail-safe iSCSI SAN by simply leveraging existing direct
attached storage (DAS) on ESX Servers. Moreover, for cost-conscious risk-averse
IT decision makers, there are two critical distinctions for the LeftHand
Networks VSA:
- This VMware appliance is a version of SAN/IQ: a storage software platform built on the Linux Kernel: It is not as an application running on a commercial OS that requires an additional license.
- Using multiple ESX servers, the LeftHand Networks appliance creates a cluster, which can withstand the loss of one or more servers.
Infrastructure virtualization became a critical focus area
for CIOs because it eliminates the constraints of physical limitations from IT
devices. By separating the functionality of a resource from the physical implementation
of a resource, system administrators are able to build logical resource pools
based on functionality and manage any member generically. That opens
significant opportunities to reduce IT operating costs and increase resource
utilization. In particular, administrators can configure the OS and
applications software that will be needed for multiple VMs as a template to
simplify and standardize system provisioning.
More importantly, storage virtualization in a VMware Virtual
Infrastructure (VI) environment is far less complex than storage virtualization
in a typical FC SAN with physical systems. A standard OS, such as Microsoft
Windows and Linux, assumes exclusive ownership of storage volumes. For that
reason, the file systems for a standard OS does not incorporate a distributed
lock manager (DLM), which is essential, if multiple systems are to maintain a
consistent view of a volume's contents. That makes volume ownership a critical
part of storage virtualization and explains why SAN management is the exclusive
domain of storage administrators at most enterprise-class sites.
This is not the case for servers running ESX. The file
system for ESX, dubbed VMFS, handles distributed file locking, which eliminates
exclusive volume ownership as a burning issue. What's more, the files in a VMFS
volume are single-file images of a VM disk—making them loosely analogous to an
ISO formatted CDROM. When a VM mounts a disk, it opens a disk-image file; VMFS
locks that file; and the VM gains exclusive ownership of the disk volume. With
volume ownership a moot issue, iSCSI becomes a perfect way to extend the
benefits of physical and functional separation via a cost-effective lightweight
SAN.
To support a VMware VI environment, VSM Labs set up two
quad-processor servers, a Dell PowerEdge 1900 and an HP ProLiant DL580 G3, as
our core ESX servers. These servers would run multiple VMs with either Windows
Server 2003 SP2 or Novel SUSE Linux Enterprise Server 10 SP1 as their OS. For
our initial SAN/IQ cluster, we ran a LeftHand VSA on our Dell PowerEdge 1900
and an HP Proliant ML350 G3.
Each VSA gets its functionality by running the latest
version of the LeftHand SAN/IQ storage software platform within a VM. Our test
scenarios focused on easy of use, performance and failover with both two and
three VSAs forming a cluster. We focused on testing flexibility because a key
component of the SAN/IQ value proposition is automation of system management
tasks. A heterogeneous cluster will test the ability of SAN/IQ to aggregate
disparate devices into a simplified uniform virtual resource pool. Nonetheless,
a homogeneous cluster will provide a virtualized with more predictable
performance characteristics.
In either case, the SAN/IQ virtual environment includes thin
provisioning, synchronous and asynchronous replication, automatic failover and
failback, and snapshots. Administrators access and manage all of these
functions via a Java-based Centralized Management Console. Nonetheless, what
distinguishes LeftHand Networks is the degree to which SAN/IQ simplifies the
configuration and management of a highly available iSCSI SAN. Using software
modules, dubbed mangers, SAN/IQ automates communications between VSAs,
coordinates data replication, synchronizes data when a VSA changes state, and
handles cluster reconfiguration as VSAs are brought up or shut down.
Even more important for small business sites and branch
offices, SAN/IQ significantly simplifies the configuration and management of
storage for its iSCSI SAN. The strategy employed by SAN/IQ to accomplish SAN
simplification is to eliminate traditional administrator tasks via automation
within the VSAs. The extensive use of automation within SAN/IQ goes as far as
entirely handling I/O load balancing, which is a critical for cluster
scalability.
The SAN/IO Central Management Console provides a
single-window view into a world of SAN storage that is distinctly hierarchical
in structure. Under this scheme, VSAs are federated to simplify the notion of
management by policy. At the top of the hierarchy is the Management Group,
which integrates a collection of distributed VSAs within specific set of
security and access policies. By allowing administrators to dynamically add or
delete a VSA, a Management Group creates a federated approach to data
integration, pooling, and sharing.
Within a Management Group, VSAs can be grouped into a
storage cluster for the purpose of aggregating local storage into a single,
large virtualized storage resource for an iSCSI SAN that is compliant with the
policies of the Management Group. The goal is to lower the cost of storage
management by hiding all of the complexities associated with the physical
aspects of direct attached storage such as data location and local ownership. Using
the SAN/IQ console, we were able to log into our site's Management Group and
gain complete access to our storage cluster and every VSA contained within our
cluster. More importantly, by virtue of the SAN/IQ hierarchy, we were able to
configure and manage VSAs holistically.
We initially created a SAN/IQ Management Group and cluster
with two VSAs: One VSA resided on the HP Proliant DL580 and the other resided
on the Dell 1900. We chose two servers with very different local storage
architectures to demonstrate the hardware independence of the VSA. To automate
decision-making, SAN/IQ implements a voting algorithm that requires a strict
majority of managers, dubbed a quorum, to agree on any course of action. That
scheme required us to activate a manager on each VSA as well as a third manager
to have a "quorum" of managers.
The easiest way to add that third manager was to put a
Virtual Manager, which was running on one of the ESX servers, into our
Management Group. A more robust solution would be to run the LeftHand Networks
Failover Manager, which is simply a VM with just the SAN/IQ manager module
within a VMware player on an existing Windows server.
What enables the advanced automation implemented by SAN/IQ
is an ingenious method for storing data in clusters. The first indication of
this scheme becomes visible, when the total storage supported by a cluster is
not the strict sum of the available direct attached storage at each of the VSA
storage modules that comprise the cluster.
As VSAs join to form a cluster, SAN/IQ examines the total
amount of direct attached (DAS) storage discovered at each ESX server host.
SAN/IQ then automatically creates a cluster-wide storage pool in which each VSA
storage module is allocated the same amount of disk space-equal to the smallest
amount of storage found in any individual VSA pool.
When a system administrator creates a virtual disk volume in
a cluster, SAN/IQ apportions the disk image file to equally sized subdisks
residing on each of the VSA storage modules in the cluster. As a result, all
I/O commands associated with that volume are spread across all of the VSAs in
that cluster. This scheme provides maximal scalability for the cluster with no
intervention or tuning from a system administrator. What's more, whenever a new
VSA joins a cluster or an existing VSA is removed, SAN/IQ immediately
restructures all of the cluster volumes as a background task.
To provide for high
availability, an administrator can assign or change the replication level of a
volume: none, two-, three-, or four-way replication. With two-, three-, or
four-way replication, each VSA replicates its portion of a volume onto one,
two, or three adjacent nodes in the cluster. That means each member of the
cluster stores a distinct subset of two, three, or four sub disk regions. In
turn, one, two, or three cluster members could fail and the entire volume would
still be available on line.
Once created, system administrators easily handle the
presentation of virtualized volumes to hosts by creating Authentication Groups
setting security policies for the virtualization of target volumes within a
Management Group. Virtualization rules can be based on the unique ID of the
client's iSCSI initiator or the Challenge-Handshake Authentication Protocol
(CHAP). More importantly, the SAN/IQ VSAs create a robust, full-featured,
general-purpose iSCSI SAN. Any system with LAN connectivity can be a SAN
client. IT can even leverage this SAN to centralize storage for all local
desktop machines in addition to any ESX servers that are not part of the
Management Group.
The next step was to grant iSCSI access rights to all of our
ESX servers—or any other systems—to the logical volumes that were being
exported by the VSA cluster. We were then able to import those volumes on any
ESX server for use by any of its VMs. On each ESX server, we essentially
re-imported storage that initially had been attached, configured, and orphaned
on a single ESX server.
The foundation for this networking legerdemain is a virtual
switched LAN created within each ESX server to handle all networking for hosted
VMs. On each ESX server, the foundation of the virtual switch was a pair of
physical Ethernet TOEs, which were teamed by ESX. All VMs, including our VSAs,
connect to the virtual switch via virtual NICs. We also needed to create a
virtual NIC for the ESX server and a port utilized by the ESX kernel to make
iSCSI connections via VMware's initiator software.
To lessen the immediate impact—which can be prodigious—of storage
provisioning with replication, SAN/IQ supports full and thin provisioning. Full
provisioning reserves the same amount of space on the SAN that is presented to
application servers. On the other hand, thin provisioning reserves space based
on the amount of actual data, rather than the total capacity that is presented
to application servers.
The traditional advantages for thin provisioning rose out of
the fact that expanding volumes on Windows and Linux servers was once a very
daunting task. Thin provisioning at the SAN avoided all the expenses related to
either immediately over provisioning storage or a later over hauling of an OS.
While advances in logical volume support within Windows and Linux now mitigate
the impact of expanding volumes within an OS, system virtualization greatly
expands the matrix of mappings from all of the systems to all of the physical
servers on which those systems may run. As a result, thin provisioning at the
SAN level becomes absolutely essential in a Virtual Infrastructure environment.
As with load balancing, SAN/IQ fully supports dynamic
allocation of storage resources by automatically growing logical volumes from a
pool of physical storage. For dynamic growth, thin provisioning is activated
for any logical drive using a simple checkbox. Once set, SAN/IQ automatically
handles all of the details and maps additional storage blocks on the fly as
real usage warrants the growth of a logical drive. From a storage management
perspective, it is only necessary to insure that an adequate number of DAS
drives are available from which physical blocks can be allocated as needed to
logical blocks.
To test both the functionality and the performance of the
VSA supported iSCSI SAN, we ran our oblLoad benchmark, which stresses the
ability of all storage and networking components in a SAN fabric to support
rapid responses to excessively high numbers of I/O operations per second
(IOPS), within Windows Server 2003 VMs on each of our core ESX servers. The
oblLoad benchmark stresses data access far more than it does data throughput,
which, in the context of iSCSI command processing, creates much more overhead
for all SAN components than a sequential throughput test.
We measured the results within the test VM and also measured
the performance of the three VSAs via VMware's VI Console client. The performance
of our oblLoad benchmark was dependent by:
- The
number of drives in each server's data array—four 15,000-rpm Ultra320 SCSI
drives on the HP Proliant ML350 server and six 10,000-rpm SATA drives on
the Dell 1900 server,
- The capabilities
of the storage-controller cache on each server—an HP SmartArray with a
128MB cache and a DELL PERC 5i with a 256MB cache.
We began the process using a VM running Windows Server 2003
on our Dell PowerEdge 1900. Quickly it became clear we were not stressing the
limits of our iSCSI cluster, but rather the limits of the local storage
systems. In particular, the VSA on the HP ProLiant ML350 G3, which was
configured with half of the controller cache and 67% of the drive spindles of
the Dell PowerEdge 1900, was roughly 50% slower processing its half of the
logical volume.
Clearly, the implication of that data is that the HP server
was slowing down cluster performance. To verify that hypothesis we used the
VMware VI console to suspend processing of the VSA running the HP ML350 server
while the VM on the Dell ESX server was running oblLoad. In essence, we created
a VSA failure.
In theory, at the point of VSA failure, the remaining two
managers should confer and move all processing for the logical drive to the
remaining VSA on the Dell server. What's more, now that the cluster was
entirely dependent on the Dell server with its more robust storage subsystem,
I/O processing should have a measurable improvement.
In practice, that is exactly what happened as we jumped from
2,000 IOPS to 3,000 IOPS. More importantly, all of that happened automatically
with no intervention on our part. Through the creation of a management
hierarchy and an automation scheme within that hierarchy, SAN/IQ creates a
high-availability scenario that can easily be managed by system administrators
in an SMB IT environment or via a lights-out management hardware located at a
remote branch office.
|